Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface
Ηλεκτρομαγνητικές Βαλβίδες Hafner - ATEX Valves - Valves with NAMUR-interface

Hafner - ATEX Valves - Valves with NAMUR-interface

Ignition protection type | EEx dm IIC T5

  • 3/2-way valves
  • 5/2-way valves

Ignition protection type | EEx d IIC T6

  • 3/2-way valves
  • 5/2-way valves

Ignition protection type | EEx m II T4

  • 2/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves

Ignition protection type | EEx ia IIC T6

  • 2/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves

Ignition protection type | EEx e mb IIC T6

  • 3/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves
 

Ignition protection type

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 310 701 Ex dG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 510 701 Ex dG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex mG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex mG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VA
NAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex iaG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 TT Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex iaG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 TT Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex e mbG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex e mbG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex e mbG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex e mbG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]
Hafner - ATEX Valves - Valves with NAMUR-interface