Ignition protection type | EEx dm IIC T5

  • 3/2-way valves
  • 5/2-way valves

Ignition protection type | EEx d IIC T6

  • 3/2-way valves
  • 5/2-way valves

Ignition protection type | EEx m II T4

  • 2/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves

Ignition protection type | EEx ia IIC T6

  • 2/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves

Ignition protection type | EEx e mb IIC T6

  • 3/2-way valves
  • 5/2-way valves
  • NAMUR-Flex | 3/2 - 5/2 valves
  • 5/3-way valves
 

Ignition protection type

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 310 701 Ex dG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 510 701 Ex dG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex mG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex mG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VA
NAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex iaG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 TT Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex iaG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 TT Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex e mbG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex e mbG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex e mbG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex e mbG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]
Hafner - ATEX Valves - Valves with NAMUR-interface

Αυτός ο ιστότοπος χρησιμοποιεί cookies για να βελτιώσει την εμπειρία πλοήγησης σας, να αναλύσει την επισκεψιμότητα και να παρέχει εξατομικευμένο περιεχόμενο και διαφημίσεις. Χρησιμοποιώντας αυτόν τον ιστότοπο, συμφωνείτε με τη χρήση των cookies σύμφωνα με την Πολιτική Cookies. Μπορείτε να ελέγξετε τις ρυθμίσεις των cookies ή να τα απενεργοποιήσετε ανά πάσα στιγμή μέσω των ρυθμίσεων του περιηγητή σας.