Pilot Operated Miyawaki - Pressure reducing Valve - Pilot Operated for steam - RE3
Pilot Operated Miyawaki - Pressure reducing Valve - Pilot Operated for steam - RE3

Miyawaki - Pressure reducing Valve - Pilot Operated for steam - RE3

■Operating principle

Changes in downstream pressure are sensed by the pilot valve mechanism (bellows connected with a pilot valve unit) through a signal line D, which connects the pilot valve regulator with the secondary pressure side.

Movement of the bellows will open or close the pilot valve, regulating the amount of steam influencing the movement of the piston, which will close or open the main valve, thus keeping downstream pressure on a stable level.

It can be used in a wide range of applications such as food industry, dyeing industry, cleaning industry, apparel industry, heating equipment and air conditioning equipment.

●Energy saving, the more you use it, the more it makes a difference.

micro bellows and a high-precision pilot valve ensures control. (Maximum primary pressure 1.6MPa, maximum pressure reduction ratio 20: 1)

●Excellent durability

Durability is outstanding due to the unique stainless steel micro bellows and overstress prevention mechanism.

  • Max. Operating Pressure
  • 1,6MPa
  • Max. Operating Temperature
  • 220℃
Standard (Options)
  • DIN
  • ANSI
Connection (Options)
  • BSP
Material (Options)
  • Brass CW 617N
Pressure Rating (Options)
  • 1,6 Mpa
 

Features

Pressure reducing valves for steam

These are automatic valves that reduce the steam supply pressure to the certified pressure for the device in use, and keep it steady.

Compact and cost effective design

It has a space saving (ultra small/lightweight). Low heat dissipation with superb energy saving properties and cost performance.

Superb durability

Offers superb durability thanks to an overstress prevention mechanism.

Pilot operated valves

The drive section detects the pressure supplied from the pilot chamber, and the degree of opening of the valve is adjusted to keep the pressure on the secondary side at a set level.

Simple pressure adjustment

Pressure adjustment can be performed by hand using a handle, with no tools required. (with lock mechanism)

Easy maintenance

It is easy disassembly and reassembly.

Uses

Suitable for a wide range of uses including devices for foodstuffs, dyeing, and cleaning as well as heating equipment and air conditioning equipment.

Dimensions/Weight

SizeDimensions (mm)Dimensions (in)Weight
LL1H1H2WLL1H1H2W(kg)(lb)
1/2”901278758743.553.42.32.92,76.0
3/4”951303.75.12,86.2
1”1001323.95.2
1 1/4”13015511173965.16.14.42.93.86,213.7
1 1/2”6,313.9
2”140157121791105.56.24.83.14.38,318.3

Specifications

odelConnection

Max. operating

pressure

Operating

pressure range

Control pressure

range

Values

Max.

pressure

reduction

ratio

Max. operating

temperature

Body

material

TypeSize(MPa)(psig)

Primary side

pressure

(MPa)

Primary side

pressure

(psig)

Secondary side

pressure

(MPa)

Secondary side

pressure

(psig)

CvKvs(℃)(℉)
RE3

Screwed

Rc,NPT

1/2”1,62320,1 - 1,614.5 - 2300,034 - 1,24.9 - 1740,80,720:1220428

Brass

C3771

3/4”1,91,6
1”3,02,6
1 1/4”4,94,2
1 1/2”6,85,9
2”12,010,3

● Offset: up to 0,03MPa (4.4psig)

● Minimum differential pressure: 0,07MPa (10.2psig)

● Minimum adjustable flow rate: 5% of the rated flow rate

● Lockup pressure :  0,03MPa (4.4psig) or lower

Capacity Chart

● How to use the chart (example)

To reduce the pressure of 400kg/h (882lb/h) of steam from 1,2MPa to 0,7MPa (174psig to 102psig)

1. Find the point at which the primary side pressure 1,2MPa (174psig) curve and secondary side pressure 0,7MPa (102psig) horizontal line intersect.

2. Trace a vertical line from the point where they intersect, and look for the smallest-sized product where the steam flow rate is 400kg/h (882lb/h) or more at the point where the vertical line you have traced intersects the horizontal size lines.

3. In this case, the pressure reducing valve with a size of 1" is optimum.

Installation Examples

■Related Products Models for reference

Sight glass TS1,  T3

Y strainer YM1,  YSF

Separator   H3,  H5

Steam trap Differs depending on conditions

Miyawaki - Pressure reducing Valve - Pilot Operated for steam - RE3