The level transmitter NRGT 26-1 / NRGT 26-1 S is a compact-type system consisting of a level measuring electrode and a level transmitter integrated in the terminal box.
The level transmitters NRGT 26-1 and NRGT 26-1S are used for continuous level monitoring in steam boilers and (pressurized) hot-water installations or in condensate and
feedwater tanks.
This product is no longer in stock
Availability date:
In conjunction with the level switch NRS 2-.. and the level controller NRR 2-.. the transmitter can be used as water level controller with MIN/MAX alarm.
The level transmitter can be used in combination with the following level switches and controllers: NRS 2-50, NRS 2-51, NRR 2-50, NRR 2-51, NRR 2-52 and NRR 2-53.
The level transmitter works according to the capacitance measurement principle and translates the level changes into a level-dependent current signal of 4-20 mA, with the length of the electrode rod determining the measuring range.
The level transmitter is installed inside steam boilers, vessels or in an external level pot. If the equipment is installed inside the boiler or vessel, a protection tube provided on side ensures correct functioning.
The level transmitter can be installed together with one GESTRA level electrode for water level limiting or for high-level alarm in a single protection tube or an external level pot.
The level transmitter can be used in electrically conductive and non-conductive fluids.
ELECTRODE
NRGT26-1-NRGT26-1S | Data Sheets (DBL) |
CONTROLLERS
NRR2-1B | Data Sheets (DBL) | ||||||
NRR2-2E | Data Sheets (DBL) | ||||||
NRR2-3 | Data Sheets (DBL) | ||||||
NRR2-40 | Data Sheets (DBL) | ||||||
NRR2-50-NRR2-51 | Data Sheets (DBL) | ||||||
NRR2-52-NRR2-53-URB50 | Data Sheets (DBL) |
SWITCHES
NRS1-1 | Data Sheets (DBL) | ||||||
NRS1-2 | Data Sheets (DBL) | ||||||
NRS1-3 | Data Sheets (DBL) | ||||||
NRS1-40 | Data Sheets (DBL) | ||||||
NRS1-40-1 | Data Sheets (DBL) | ||||||
NRS1-41 | Data Sheets (DBL) | ||||||
NRS1-42 | Data Sheets (DBL) | ||||||
NRS1-50-FOR-ONE-ELECTRODE | Data Sheets (DBL) | ||||||
NRS1-50-FOR-TWO-ELECTRODES | Data Sheets (DBL) | ||||||
NRS1-51 | Data Sheets (DBL) | ||||||
NRS1-52 | Data Sheets (DBL) | ||||||
NRS1-53 | Data Sheets (DBL) | ||||||
NRS1-54-NRS1-55 | Data Sheets (DBL) | ||||||
NRS1-5B | Data Sheets (DBL) | ||||||
NRS1-7 | Data Sheets (DBL) | ||||||
NRS1-8 | Data Sheets (DBL) | ||||||
NRS1-9 | Data Sheets (DBL) | ||||||
NRS2-1 | Data Sheets (DBL) | ||||||
NRS2-3 | Data Sheets (DBL) | ||||||
NRS2-4 | Data Sheets (DBL) | ||||||
NRS2-40 | Data Sheets (DBL) | ||||||
NRS2-5 | Data Sheets (DBL) | ||||||
NRS2-50-NRS2-51 | Data Sheets (DBL) | |