Features
Pressure reducing valves for liquids and gases
The model REA20 is a direct acting pressure reducinf valve designed for use of compressible media, such as air and various gasses and for incompressible media such as water, oil and others.
Due to carefully selected springs a wide range of pressure applications is available.
As option the valve can be equipped with a pressure gauge on the valve body.
Operating features of direct acting pressure reducing valves
Pressure changes on the secondary side are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to keep the pressure on the secondary side at a set level.
Maximum pressure reduction ratio 25:1
Uses
Perfect for cleaning devices, foodstuff devices, and other forms of compact steam equipment.
Dimensions/Weight

Size (DN) | Dimensions (mm) | Kvs Value | ||||
L | H | h | ||||
PN63-100 | ||||||
15 | 210 | 315 | 82 | 1,8 | ||
20 | 230 | 66 | 3,2 | |||
25 | 230 | 66 | 5,0 | |||
32 | 260 | 81 | 7,9 | |||
40 | 260 | 83 | 13,0 | |||
50 | 300 | 477 | 100 | 20,0 | ||
65 | 340 | 520 | 113 | 34,0 | ||
80 | 380 | 648 | 140 | 51,0 | ||
100 | 430 | 670 | 154 | 80,0 |
Specifications
Body Material
Stainless steel
GX5CrNiMo19--11-2
(1.4408)
Body design conditions
PN40 | |||
Max. design pressure (MPa) PMA | 4,0 | ||
Max. design temperature (℃) TMA | 400 | ||
Max. operating pressure (MPa) PMO | 4,0 | ||
Max. operating temperature (℃) TMO | 400 |
Pressure - Temperature rating
PN | Temperature℃ | |||||||||||
-10・・・+50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | |||||
Pressure MPa | ||||||||||||
PN40 | 4,0 | 3,7 | 3,4 | 3,1 | 2,9 | 2,8 | 2,7 | 2,6 |
Secondary pressure ranges
Secondary pressure range | DN15-DN40 | DN50 | DN65 | DN80 | DN100 | DN125-DN200 |
MPa | Spring number per size | |||||
0,05-0,1 | 9 | 28 | 27 | 38 | 37 | On request |
0,1-0,16 | 8 | 27 | 26 | 37 | 36 | |
0,16-0,25 | 7 | 26 | 25 | 36 | 35 | |
0,25-0,4 | 6 | 25 | 24 | 35 | 34 | |
0,4-0,63 | 5 | 24 | 23 | 34 | 33 | |
0,63-1,0 | 4 | 23 | 22 | 33 | 32 | |
1,0-1,6 | 3 | 22 | 21 | 32 | 32 |
Secondary pressure ranges higher than 1,6 MPa and lower than 0,05 MPa on request available.
Capacity Chart